Product

Home » Product
 RH-3AV33YH Three-Phase Digital Display Voltmeters

Measure three-phase AC voltage or DC voltage with high-precision.
Provide LED display and local data query.
Programmable voltage transformation ratio.
Support RS-485 communications and Modbus-RTU protocol.
Support switch input, switch output and analog output.
Power supply: AC / DC 80V~270V、 A C 2 2 0 V、A C 3 8 0 V、A C 100V
There are various choices of dimensions to meet the requirements of different electrical circuit enclosure.

Technical Index

Accuracy Measurement

Voltage class: 0.5

Input Measurement

Wiring 3-phase 3-wire、3-phase 4-wire
Rated value AC 57.7V、AC 100V、AC 220V、AC 380V

Overload Sustained: 1.2 times; Instantaneous: 2 times/ 1s

Power consumption <1VA (per phase)

Impedance >300mΩ

Frequency 45~65Hz

Power supply
Working range
A C / D C 8 0 V ~ 2 7 0 V、A C 2 2 0 V、A C 3 8 0 V、A C 1 0 0 V

Power consumption < 4 V A

Functional Module

Communication interface 1 loop RS-485 Communication, MODBUS-RTU protocol Baud rate: 2400 ~ 19200bps, Default: 2400bps

Switching value input 4 loops switching value input, dry joint

Switching value output 3 loops relay output, capability: AC 250V/5A,DC 30V/5A

Transmission output 3 loops analog output: 0/4~2 0 m A o r 0~5 / 1 0 V

Environment

Operational environment - 1 0℃~ + 5 5℃

Storage environment - 2 5℃~ + 7 0℃

Relative humidity ≤9 3 %,in the place without corrosive gas

Height above sea level ≤2 5 0 0 m

Safety

Insulation resistance > 1 0 0 MΩ
AC withstand voltage A C 2 K V

Electro Magnetic CompatibilityElectro-Static discharge class 4
Electrical Fast Transient pulse train class 4
Electrical surge class 4

Outline Dimension

External Dimension( m m ) 1 2 0×1 2 0;8 0×8 0;9 6×4 8;9 6×9 6;8 0×8 0;4 8×4 8;1 2 0 x 6 0;1 6 0 x 8 0Cutout Dimension( m m ) 1 1 1×1 1 1;7 6×7 6;9 2×4 5;9 2×9 2;6 8×6 8;4 5×4 5;1 1 4 x 5 6;1 5 2 x 7 6

Specification Matching

Note: The number of optional extended functions would be the maximum number we can extend in normal conditions.
If you have any special request, please contact with our technical department.

Terminal Connection Diagram

Note:In case of any discrepancy, the diagram painting on the meter housing shall prevail.

Typical Wiring Diagram

 

Contact Online helenhuang03@hotmail.com 37652761 helenhuang03 0086-577-62780017 Sales@nicead-electrical.com